home *** CD-ROM | disk | FTP | other *** search
/ IBM OEM Software Product … CD For PC Manufacturers / IBM OEM Software - Product Sampler CD for PC Manufacturers.iso / InternetIntranets / Notes / LOTUS027.DSK / MODEMS / ULTRA14.MDM < prev    next >
Text File  |  1994-11-23  |  3KB  |  113 lines

  1. ; Hayes V-Series ULTRA & OPTIMA Smartmodem 14400
  2.  
  3. ;===============================================
  4. ; Last revision date: 11/23/94 (update this date
  5. ; each time you edit; it is also advisable to rename
  6. ; your edited file [use Save As, rather than Save 
  7. ; option] to avoid later confusion and to keep the 
  8. ; original .MDM file intact).
  9.  
  10. ; NOTE: Refer to the file TEMPLATE.MDM (A Sample Modem 
  11. ; Command File) for a description of modem command 
  12. ; files and how they work. "A Sample Modem Command 
  13. ; File" is user selectable within the Lotus Notes 
  14. ; Setup dialog "Modem Type" listbox in which you found 
  15. ; this modem command file (see end of listings, 
  16. ; beginning with a period) and is a printable ASCII 
  17. ; text file (approximately 15 pages). 
  18.  
  19. ; Additional information may be obtained from either of 
  20. ; the two so-called "generic" modem command files 
  21. ; (alphabetically listed under letter G, designed for 
  22. ; use with Notes Releases 2.x and 3.x, 9600 bps and 
  23. ; 14400 bps maximum, respectively), each of which may 
  24. ; first be tried as-is with unlisted modems, then edited 
  25. ; if required (within the Notes edit box, or outside of 
  26. ; Notes, with any text editor) according to the printed 
  27. ; instructions within each file, and in compliance with 
  28. ; the vendor's command set, result codes, DIP switch 
  29. ; settings, and technical specifications as listed in 
  30. ; the equipment's users manual.
  31.  
  32. ; For the specific modem(s) listed under this heading:
  33. ;=====================================================
  34.  
  35. [attributes]
  36.  
  37. MODELS=Hayes V-Series ULTRA & OPTIMA Smartmodem 14400 
  38. NULL MODEM=0
  39. MAXIMUM SPEED=57600
  40. DEFAULT SPEED=57600
  41.  
  42. [commands]
  43.  
  44. ESCAPE=+++
  45. ATTENTION=ATE0V1
  46. HANGUP=ATH0
  47. SETUP=AT&F
  48. SETUP=ATE0V1
  49. SETUP=ATN1Q0W1X4&C1&D3&L0&Q5&S0&U0S0=0S37=0S95=44
  50. RTS/CTS ENABLED=AT&K3&R0
  51. RTS/CTS IGNORED=AT&K0&R1
  52. VOLUME OFF=ATM0
  53. VOLUME LOW=ATM1L1
  54. VOLUME MEDIUM=ATM1L2
  55. VOLUME HIGH=ATM1L3
  56. ANSWER=ATA
  57. MANUAL DIAL=ATX3S9=1D
  58. AUTO DIAL SETUP=ATS9=6
  59. AUTO PULSE DIAL=ATDP
  60. AUTO TONE DIAL=ATDT
  61. AUTO DIAL SUFFIX=,
  62.  
  63. [responses]
  64.  
  65. OK=OK
  66.  
  67. BUSY=BUSY
  68.  
  69. NO ANSWER=NO ANSWER
  70.  
  71. NO CARRIER=NO CARRIER
  72.  
  73. NO DIALTONE=NO DIALTONE
  74.  
  75. ERROR=ERROR
  76.  
  77. RING=RING
  78.  
  79. CONNECT, 57600=CONNECT 57600
  80. CONNECT, 57600=CONNECT 57600/ARQ
  81.  
  82. CONNECT, 38400=CONNECT 38400
  83. CONNECT, 38400=CONNECT 38400/ARQ
  84.  
  85. CONNECT, 19200=CONNECT 19200
  86. CONNECT, 19200=CONNECT 19200/ARQ
  87.  
  88. CONNECT,  9600=CONNECT 9600
  89. CONNECT,  9600=CONNECT 9600/ARQ
  90.  
  91. CONNECT,  4800=CONNECT 4800
  92. CONNECT,  4800=CONNECT 4800/ARQ
  93.  
  94. CONNECT,  2400=CONNECT 2400
  95. CONNECT,  2400=CONNECT 2400/ARQ
  96.  
  97. CONNECT,  1200=CONNECT 1200
  98. CONNECT,  1200=CONNECT 1200/ARQ
  99.  
  100. CARRIER,,14400=CARRIER 14400
  101.  
  102. CARRIER,,12000=CARRIER 12000
  103.  
  104. CARRIER,, 9600=CARRIER 9600
  105.  
  106. CARRIER,, 7200=CARRIER 7200
  107.  
  108. CARRIER,, 4800=CARRIER 4800
  109.  
  110. CARRIER,, 2400=CARRIER 2400